- Dual
source of charging from Solar Power as well as from Grid Power.
- Power card with inbuilt
PWM based Solar Charge Controller of 50A for maximum utilization of solar power.
- Intelligent
selection of ‘Battery Boost Voltage’ to avoid un-necessary heating of battery
during charging.
- Intelligent
selection of ‘Battery Low Shutdown’ for longer backup according to load
conditions.
- Regular priority
of Solar Power to give maximum benefits
from solar energy
to run the load or charge
the battery.
- 30% AVR
function below 180V Grid Input.
- Storage of
Solar Power consumed from the day of installation.
- CC &
CV mode for every 0.1V increment of battery
voltage.
- Priority
to maintain gravity of battery in CV mode with different time zone at regular
interval of time.
- Maximum
usage of Solar Power to minimize the electricity bill and being eco-friendly.
- Display
maximum and useful parameters on LCD according to customer needs.
- Pure Sine
Wave output with less harmonic distortions.
- Battery
low cut off and overcurrent sensing with auto
retries.
- Double
stage MOSFET over current protection at priority.
- Thermal
trip with auto recovery.
- Cooling
Fan will work: (a) Forced Cooling- Load ≥50%, Charging Current ≥8A, MOSFETs
temperature ≥50OC. (b)
Normal Cooling-Every 3 minutes for 10 seconds.
- Reverse
current protection from battery to solar in absence of solar power.
- Grid Power
utilization according to presence of Solar Power.
- Critical parameters setting according to battery & grid conditions.
DISPLAYING PARAMETERS ON LCD
- Model VA & Capacity
- Battery Voltage
- PV Charging Current
- Grid I/P Voltage
- Grid Charging Current
- AC Output Voltage
- Discharging Current
- Load Percentage
- Mode UPS/Normal
- Battery Status
- PV Status
- Grid Status
- Load Status
- Consumed PV Power
- Instant PV Power
- Thermal Trip
- PV Reverse
- Short-circuit
- Battery Low/High
- Grid MCB/Fuse Trip
- Battery Overload Trip
TECHNICAL SPECIFICATIONS
Parameters | TPPW9001250PL | TPPW11001250PL | TPPW15002450PL | TPPW22002450PL |
Nominal Battery Voltage | 12V | 12V | 24V | 24V |
PV Input | 600Wp | 800Wp | 1200Wp | 1600Wp |
No Load Output Voltage | 230V ± 2% | 230V ± 2% | 230V ± 2% | 230V ± 2% |
Full Load DC Current | 50A ± 1.0A | 67A ± 1.0A | 50A ± 1.0A | 67A ± 1.0A |
Full Load O/P Voltage | ≥180V | ≥180V | ≥180V | ≥180V |
Output Voltage Waveform | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave |
PWM Charge Controller | 50A | 50A | 50A | 50A |
Input AC Voltage (Normal) | 90V-290V ± 2% | 90V-290V ± 2% | 90V-290V ± 2% | 90V-290V ± 2% |
Input AC Voltage (UPS Mode) | 145V-260V ± 2% | 145V-260V ± 2% | 145V-260V ± 2% | 145V-260V ± 2% |
Change Overtime (Maximum) | ≤ 7msec | ≤ 7msec | ≤ 7msec | ≤ 7msec |
Grid Charging Current | 14.5A ± 1.0A | 14.5A ± 1.0A | 14.5A ± 1.0A | 14.5A ± 1.0A |
Default Boost Voltage | 14.4V ± 0.2V | 14.4V ± 0.2V | 28.8V ± 0.2V | 28.8V ± 0.2V |
Float
Voltage | 13.7V ± 0.2V | 13.7V ± 0.2V | 27.4V ± 0.2V | 27.4V ± 0.2V |